UPS F.908

 

Pack :

1 pail : 25 ltr
1 drum : 200 ltr


UPS F.908

MULTI FUNCTION PROGRAM-FOOD GRADE

PRODUCT DESCRIPTION :
UPS F. 908 is a multifunctional boiler treatment designed specifically for use in applications that utilize low alkalinity, hard make up UPS. These type UPS require an alkalinity builder, and higher levels of phosphate.

PRODUCT COMPONENTS :                             Sodium Sulfite
                                                           Polyphosphate
                                                           Phosphonate
                                                           Polymer

                                                 Antifoam 

FEATURES                                      BENEFITS
Contains alkalinity builder                 Appropriate for building alkalinity.
Contains higher level of phosphate    Appropriate for use in high hardness waters.
Contains Polymer                             Additional threshold inhibitor with good iron.
                                                      dispersancy properties.
Antifoam                                         Reduces risk of carryover           
One drum treatment                         Convenience    
 

COMMENTS
This multifunctional boiler treatment is designed specifically for use in applications where low alkalinity, and hardness waters exist. Care should always be used when selecting a multifunctional boiler treatment to choose one which appropriate for the particular make up water and concentration cycles of the specific application.

DOSAGE :
Before calculating a dosage with any multifuctional boiler treatment one should first confirm that the correct product has been chosen. The first step in this selection process is to analyze the make up water determining the total alkalinity and total hardness levels. Then refer to the product selection graphs, and knowing the approximate cycles of concentration based on make up, determine which product would be appropriate. One this is done, one should work through the dosage calculation to calculate the exact amount of product to be dosed for any particular application. 

FEEDING POINTS
A great advantages of multifuctional boiler treatment is the conveneince they offer to small and medium boiler applications. For this convenience however, there are certain limitations. One such limitations is that there  does not exist an optimum feed point for these type products. One must realize that no matter where these type products are applied, there will be certain advantages and disadvantages to be aware of. The following  table illustrates this point.

FEEDING POINTS
A great advantages of multifuctional boiler treatment is the conveneince they offer to small and medium boiler applications. For this convenience however, there are certain limitations. One such limitations is that there  does not exist an optimum feed point for these type products. One must realize that no matter where these type products are applied, there will be certain advantages and disadvantages to be aware of. The following  table illustrates this point.

 

FEED  POINT

ADVANTAGES

           DISADVANTAGES

Feed Water Tank/DA

Best feed location for optimum
Use of sulfite for oxygen removal

Precipitation and possible scaling in the feed water tank

Feed Water Line

 

No precipitation in feed water
Tank

No oxygen corrosion protection of feed water tank. Precipitation and possible scaling of feed water line

Directly to Boiler

 

Best location for optimum use of phosphate

Poor location for oxygen removal by sulfite. Possible oxygen corrosion may occur to system

CONTROL
All in one drum boiler treatment have verious formulations to handle different types of water based on hardness and alkalinity. Although the phosphate calculation is used starting point in the dosage of this, one should not totally rely on the phosphate test for the control of this product. But rather, should  also  monitor sulfite and alkalinity residuals in the boiler. The control ranges for use these treatment are 30 – 50 ppm of sulfite (as SO3), 20 – 40 ppm of the phosphate (as PO4)  and 300 – 850 ppm P – alkalinity (as CaCO3). Keep in mind that one of the drawbacks of these using product is that if one parameter falls out of range it cannot be adjusted without adjusting all other parameters. Sulfite will typically be the most difficult treatment residual to maintain with these product, and therefore it is necessary to sometimes supplement the program with additional sulfite in  order to prevent excessive levels of phosphate  and /or alkalinity.

REGULATORY APPROVALS :
UPS F. 908 is formulated compliance with FDA regulations for boiler product which are utilized in boilers that produce steam which may contact food or food product. UPS F. 908 is approved for use in USDA inspected plants.